House has a 2,400 sq ft attic footprint.

Prompt as given to every model

House has a 2,400 sq ft attic footprint. How much vent area do I need, and how should I split it?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Nemotron 3 Ultra 550BScore —

Minimum Net Free Vent Area (NFVA): 10 ft² (1,440 in²)

Code Basis (IRC R806.1 / IBC 1202.2):

  • Standard Rule (1/150): 2,400 ft² ÷ 150 = 16 ft² (2,304 in²) NFVA.
  • Reduced Rule (1/300): Permitted only if both conditions are met: 1. Climate Zones 6, 7, 8: Class I or II vapor retarder on the warm-in-winter side of ceiling insulation. 2. Balanced Ventilation: 40%–50% of vent area at upper portion (ridge/upper gable), balance at eave/soffit.
  • Calculation (1/300): 2,400 ft² ÷ 300 = 8 ft² (1,152 in²) NFVA.

Recommendation: Design for 10 ft² (1,440 in²) NFVA (approx. 1/240 ratio). This exceeds the 1/300 minimum, provides a safety margin for partial blockage, and works in all climate zones without relying on a perfect vapor retarder.

Split (Critical for Performance):

  • Intake (Soffit/Eave): 60% = 6.0 ft² (864 in²) NFVA.
  • Exhaust (Ridge/Upper Gable): 40% = 4.0 ft² (576 in²) NFVA.

Why 60/40? Positive pressurization of the attic prevents pulling conditioned air from the living space through ceiling leaks (can lights, top plates). Code minimum is 50/50; 60/40 intake-heavy is best practice.

Product Selection (Check Manufacturer's NFVA Rating):

  • Continuous Ridge Vent: ~18 in² NFVA per linear foot. Need 32 LF (576 ÷ 18).
  • Continuous Soffit Vent: ~9–12 in² NFVA per linear foot. Need 72–96 LF (864 ÷ 12 to 864 ÷ 9).
  • Individual Soffit Vents (16"x8"): ~50–60 in² NFVA each. Need 15–17 vents.

Hard Requirements:

  1. Baffles/Rafter Vents: Install at every rafter bay to prevent insulation from blocking soffit intake.
  2. Air Seal First: Seal all attic floor penetrations (top plates, chases, recessed lights) before insulating/venting. Ventilation cannot fix air leakage.
  3. No Mixing: Do not combine ridge vents with gable vents or power fans; they short-circuit airflow.
754 tokens · 15.0s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Super 120BScore —

For a 2,400 sq ft attic footprint, the required net free vent area (NFVA) depends on whether you’re using a balanced system (soffit + ridge) or a 1:300 ratio per the International Residential Code (IRC) and most building codes.

✅ Required Vent Area (IRC R806.2)

  • Standard ratio: 1 sq ft of NFVA per 300 sq ft of attic floor area → 2,400 ÷ 300 = 8 sq ft total NFVA.
  • Exception: If you have a vapor retarder on the warm-in-winter side of the ceiling (common in most homes), you can use the 1:150 ratio → 2,400 ÷ 150 = 16 sq ft total NFVA. → But note: Most codes now require the 1:300 ratio unless you have a continuous vapor barrier AND balanced ventilation — so 8 sq ft is the safer, more universally accepted minimum.

✅ Best Practice: Split 50/50 (Soffit : Ridge)

To ensure proper airflow (cool air in soffits, warm air out ridge), split the total NFVA evenly:

  • Soffit vents: 4 sq ft NFVA
  • Ridge vents: 4 sq ft NFVA

🔧 Practical Installation Tips

  • Soffit vents: Use continuous vented soffit panels or individual baffled vents. Avoid blocking with insulation — install baffles (e.g., AccuVent) to maintain airflow path.
  • Ridge vents: Use a continuous ridge vent with external baffle (e.g., GAF Cobra, Owens Corning VentSure) for wind-driven rain resistance and consistent flow.
  • Avoid: Powered attic ventilators unless paired with adequate soffit intake — they can depressurize the attic and pull conditioned air from living space.
  • Check: Ensure no insulation blocks soffits. Use rafter baffles from soffit to ridge.

⚠️ When to Call a Pro

If your roof has complex geometry (hips, valleys, dormers), or you’re unsure about vapor barrier presence or existing vent blockage, consult a licensed roofing contractor or home energy auditor. Improper venting causes moisture buildup, mold, ice dams, and shingle failure.

Bottom line: Aim for 8 sq ft total NFVA, split 4 sq ft soffit / 4 sq ft ridge. Keep it balanced and unobstructed. (Source: IRC 2021 R806.2, ASHRAE 62.2)