Based on the National Electrical Code (NEC), here are the areas where GFCI protection is required for receptacles in a new house:
1. All 15A and 20A, 125V Receptacles in:
- Bathrooms: All 15A and 20A, 125V receptacles installed in or on the wall behind the sink (NEC 210.8(A)(1)).
- Garages: All 15A and 20A, 125V receptacles installed in garages (NEC 210.8(A)(2)).
- Outdoors: All 15A and 20A, 125V receptacles installed outdoors (NEC 210.8(A)(3)).
- Crawl Spaces: All 15A and 20A, 125V receptacles installed in crawl spaces (NEC 210.8(A)(4)).
- Basements: All 15A and 20A, 125V receptacles installed in unfinished areas of basements (NEC 210.8(A)(5)).
- Under Stairs: All 15A and 20A, 125V receptacles installed in areas under stairs (NEC 210.8(A)(6)).
- Lavatories (in dwelling units other than dwelling units with 3 or more stories): All 15A and 20A, 125V receptacles installed in or on the wall behind the sink (NEC 210.8(A)(7)).
2. Kitchen Countertop Receptacles:
- All 15A and 20A, 125V receptacles installed to serve countertop outlets in kitchens (NEC 210.8(A)(6)).
3. Laundry Areas:
- All 15A and 20A, 125V receptacles installed in laundry areas (NEC 210.8(A)(10)).
4. Utility Sinks:
- All 15A and 20A, 125V receptacles installed in areas with a sink or similar fixture (NEC 210.8(A)(11)).
Important Notes:
- GFCI Protection Methods: You can use GFCI receptacles or GFCI circuit breakers to provide this protection.
- Local Codes: Always check local electrical codes, as they may have additional requirements or be more stringent than the NEC.
- Licensed Electrician: If unsure about any aspect of installation, consult a licensed electrician.
This list covers the primary areas where GFCI protection is mandated by the NEC for dwelling units.