Attached two-car garage with a bedroom above it.

Prompt as given to every model

Attached two-car garage with a bedroom above it. What drywall does code want on the garage ceiling and on the walls between the garage and the house?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Laguna S 2.1Score —

IRC Requirements (2018+):

Garage Ceiling (with habitable room above):

  • Drywall: ½" minimum gypsum board (Type X not required by code, but recommended)
  • Ceiling joists: Must support 1-hour fire rating
  • Installation: All joints taped and finished per GA-216

Walls between garage and house (fire separation):

  • Drywall: ½" minimum gypsum board on garage side only
  • Fire rating: ½-hour fire wall (IRC Section R309.6.1)
  • Coverage: Full height of wall, including around garage door openings
  • Penetrations: All electrical boxes must be sealed, HVAC ducts require approved fire dampers

Key Details:

  • Garage door area: Drywall extends to underside of garage door header
  • Foundation wall: If garage is below grade, foundation walls also need ½" drywall
  • Ceiling slope: If ceiling is sloped, drywall covers entire surface

Safety Note: While ½" regular drywall meets minimum code, Type X (fire-rated) drywall is strongly recommended for both applications, especially with a bedroom above. This provides better fire protection and may reduce insurance liability.

Bottom line: ½" gypsum board on garage ceiling and garage-side of shared walls. Type X is the safer choice.

Always check local amendments - some jurisdictions require 5/8" Type X throughout.

414 tokens · 10.1s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Ultra 550BScore —

Garage Ceiling (under bedroom): 5/8" Type X gypsum board. IRC R302.6 / IBC 714.4.2: The garage–dwelling separation requires a 1-hour fire-resistance rating. A single layer of 5/8" Type X on the garage side of the ceiling assembly satisfies this (UL Design L501, etc.). Standard 1/2" does not.

Garage–House Common Walls: 5/8" Type X gypsum board on the garage side. IRC R302.6: Same 1-hour rating. One layer of 5/8" Type X on the garage face of the wall meets code. If the wall is load-bearing or you want rating from both sides, apply 5/8" Type X both faces.

Key details:

  • Tape joints and coat fasteners; untreated joints = no rating.
  • Extend board to the underside of the roof deck or install fireblocking at the top plate (R302.11).
  • Penetrations (ducts, pipes, wires) must be firestopped per UL system or IRC R302.4.1.2.
  • No 1/2" "fire-code" board—only 5/8" Type X (or proprietary 1/2" Type X if listed for 1-hr in that assembly).

Local amendments can require 5/8" Type X on both sides of the wall or on the bedroom ceiling too. Verify with your building department before hanging.