IRC Requirements (2018+):
Garage Ceiling (with habitable room above):
- Drywall: ½" minimum gypsum board (Type X not required by code, but recommended)
- Ceiling joists: Must support 1-hour fire rating
- Installation: All joints taped and finished per GA-216
Walls between garage and house (fire separation):
- Drywall: ½" minimum gypsum board on garage side only
- Fire rating: ½-hour fire wall (IRC Section R309.6.1)
- Coverage: Full height of wall, including around garage door openings
- Penetrations: All electrical boxes must be sealed, HVAC ducts require approved fire dampers
Key Details:
- Garage door area: Drywall extends to underside of garage door header
- Foundation wall: If garage is below grade, foundation walls also need ½" drywall
- Ceiling slope: If ceiling is sloped, drywall covers entire surface
Safety Note: While ½" regular drywall meets minimum code, Type X (fire-rated) drywall is strongly recommended for both applications, especially with a bedroom above. This provides better fire protection and may reduce insurance liability.
Bottom line: ½" gypsum board on garage ceiling and garage-side of shared walls. Type X is the safer choice.
Always check local amendments - some jurisdictions require 5/8" Type X throughout.